SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, PROGRAMMER ACTION: Change your job control statement to either use simplified job control or to correctly decribe the volumes required to access your base cluster and its alternate indexes. PROGRAMMER ACTION: Change your program to specify MACRF=OUT in the ACB if you want to process empty files. Explore How to Obtain and Display the File Status after attempting to access a data file or VSAM data set. have a peek at this web-site

PROGRAMMER ACTION: Install the VSE/VSAM Space Management for SAM Feature in your system and rerun the job. Return Code=08 Action=Request The requested record is contained in a control interval that is already held in exclusive control by another request. For example, a permanent I/0 error may have occurred when VSAM was reading or writing a catalog entry or a catalog recovery area record. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, visit

Vsam Catalog Return Code Is 48 - Reason Code Is Igg0clfo-28

X'C8' 200 Return Code=08 Action=Request An addressed or control-interval access is attempted via a path. This is made even worse by my pretty extensive set of JCL I've gathered over the years. PROGRAMMER ACTION: Ensure that in the SYNAD exit routine your program issues a DUMP macro.

X'10' 016 Return Code=00 Action=Request A control-area split occurred because there was not enough space to make an index entry in a sequence set-record. Return Code=08 Action=Request Invalid or conflicting RPL options or parameters: SKP together with BWD. Other possible causes are: 1. Iec331i The maximum number of extensions for the file has been exceeded.

Save the dump you obtain and the SYSLOG output for later problem determination. Igg0cleg-42 DISP=NEW was specified for an input file. X'6E' 110 Return Code=08 Action=OPEN You attempted to open for input only (ACB MACRF=IN) a file which was empty (no record in it) or a file was not properly closed on X'32' 050 Return Code=08 Action=OPEN One or more VSAM processing modules cannot be loaded because either the GETVIS area or the partition is too small.

X'0F' 015 Return Code=04 Action=COMM The work area provided in your program does not begin on a fullword boundary (GENCB or SHOWCB). Idc3007i PROGRAMMER ACTION: Change your program to build a resource pool that can accommodate the key length of the file being opened. X'5C' 092 Return Code=04 Action=OPEN Warning: MACRF = LSR (local shared resources) is specified, but no OPEN/CLOSE/TCLOSE message area was specified. PROGRAMMER ACTION: If data integrity problem arise, revert to a valid backup copy of the file.

Igg0cleg-42

It was exported with the TEMPORARY and INHIBITSOURCE options and updating is not permited. website here No space of the required class is available for additional secondary allocations. Vsam Catalog Return Code Is 48 - Reason Code Is Igg0clfo-28 First thought: NextGen'ers are going to love this. Idcams Return Codes PROGRAMMER ACTION: Use Access Method Services BLDINDEX command to initialize the alternate index.

Extended File Status, nnn-xx The first character of the File-Status-Key is known as status-key-1. http://getbetabox.com/return-code/idcams-vsam-open-return-code-is-160.html Return Code=08 Action=Request An addressed request was issued for a relative-record file. Alternate indexes are incorrectly defined (Key length or position, duplicates or sparse parameters). 2. Status-key-2Decimal Status-key-2Hex Description 9000 00 No further information. 9001 01 Insufficient buffer space. Igd17103i

This is an invalid prefix. The Recording Mode is Variable or Fixed or not defined the same as when the file was created. 3. If a relative-record file was being accessed, VSAM may have detected a deleted or invalid record (empty slot) at the accessed record location. Source It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement.

X'47' 071 Return Code=08 Action=OPEN Allocation specifications for implicit define conflict with the file characteristics specified in the DLBL. Idc3014i MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register Profile Log in to check your private messages Log in Alternate Index Definition for IAM files MVSFORUMS.com During sequential or skip-sequential access, a subsequent request will access records with a higher alternate key than the one in error.

If you determine the contention is caused by other jobs (either in your system or another system) using the same files as your job, attempt to reschedule your job at a

Possible causes:Attempting to WRITE or REWRITE a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated file.Attempting PROGRAMMER ACTION: Because this information was collected during OPEN processing, it cannot be printed. X'0E' 014 Return Code=04 Action=CBMN The specified parameters are inconsistent ( GENCB, MODCB, SHOWCB, or TESTCB). Vsam Error Codes Return Code=08 Action=Request The maximum number of pointers in the alterenate index has been exceeded.

Comments or Feedback This document was created and is copyrighted and maintained by SimoTime Technologies. I keep hearing that JCL is reused to the point that no one writes their own anymore, and I think that's pretty true. OPEN with RESET was specified in the ACB and the file is being accessed by another ACB. http://getbetabox.com/return-code/vsam-close-return-code-is-184.html PROGRAMMER ACTION: Regenerate the file specifying a larger primary and/or secondary allocation in the Access Method Service DEFINE command, so that a larger control area size will be used by VSAM.

For additional information about SimoTime Services or Technologies please send an e-mail to: [email protected] or call 415 883-6565. Some data control intervals could not be used in the control area that was split. Return Code=08 Action=Request VSAM detected a record out of sequence in a key-sequenced or relative-record file (possibly a duplicate key or record number). The documentation and software were developed and tested on systems that are configured for a SimoTime environment based on the hardware, operating systems, user requirements and security requirements.

The error may be caused by such conditions as VSAM finding an unformatted record when expecting a formatted record, a volume containing data other than that expected, or an I/O error. Indicates a duplicate key condition. Possible causes:For a READ statement the key value for the current key is equal to the value of that same key in the next record in the current key of reference.For These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.

PROGRAMMER ACTION: Change your DLBL statement to specify DISP=OLD or change the ACB to specify MACRF=(OUT,NRS). The device on which the volume is mounted "down" (Job Control command DVCDN). Rerun the job. Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web