Any suggestions where to tackle this problem is welcomed. 0 Comment Question by:bobstits Facebook Twitter LinkedIn https://www.experts-exchange.com/questions/23957572/W32Time-Error-Event-ID-29-NtpClient-has-no-source-of-accurate-time.htmlcopy LVL 24 Best Solution byryansoto What I have done is set up one The standard profile controls the firewall when not connected to your domain, so they could not synchronize with your DCs anyway. TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server SharePoint Products Skype for Business See all products This event ID is often seen in combination with W32Time Event ID 24 (Warning). http://getbetabox.com/event-id/windows-2003-event-id-50-w32time.html

Covered by US Patent. NtpClient has no source of accurate time. Unauthorized reproduction forbidden. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by HomeForumsMIS/ITOperating Systems - Hardware IndependentMicrosoft: Windows Server 2003 Forum event https://social.technet.microsoft.com/Forums/windowsserver/en-US/cbef4cca-8b4f-4695-bc9b-078c964353d6/windows-2003-server-event-id-29-w32time?forum=winservergen

Event Id 29 W32time Server 2003

Go to this key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Netlogon" and modify the DependOnService string adding DNS after LanmanWorkstation. Cory Red Flag This Post Please let us know here why this post is inappropriate. x 91 Anonymous If the NetLogon service is stopped and you are set to update your time from a DC, you will get this error. Event Source: W32Time Event ID: 29 Description: The time provider NtpClient is configured to acquire time from one or more time sources, however none of the sources are currently accessible.

After starting them, the log cleared up. NtpClient has no source of accurate time. To open a command prompt as an administrator, click Start. The Time Provider Ntpclient Is Configured To Acquire Time From One Or More Time Sources How to configure Windows Time Server to use an external time source on a Windows 2003 Related Topics Event ID Troubleshooting Event ID: 2011 - Not enough server storage is available

x 132 Anonymous The following fixed a rogue workstation for me. Event Id 1116 Microsoft Antimalware At the command prompt, type W32TM /resync, and then press ENTER. This domain controller will be discarded as a time source and NtpClient will attempt to discover a new domain controller from which to synchronize. In Start Search, type Command Prompt.

In another case, I had this problem with a W2K3 Server synchronizing with the DC. The Time Provider Ntpclient Cannot Reach Or Is Currently Receiving Invalid Marked as answer by Sainath IRP_MJ_CREATEMVP, Moderator Wednesday, August 25, 2010 7:07 AM Monday, October 19, 2009 6:51 PM Reply | Quote 0 Sign in to vote Hi, This error may x 96 Bob Heitzman If you are behind a firewall, you may be blocked from accessing NTP services on the Internet. But if for any reason it goes to any other public time server and fails synchronizing the time, you may find errors and warnings as i was receiving on one of

Event Id 1116 Microsoft Antimalware

You’ll be auto redirected in 1 second. Finally, run W32TM /resync /rediscover followed by W32TM /resync /nowait. Event Id 29 W32time Server 2003 No attempt to contact a source will be made for 15 minutes. Event Id 29 W32time Xp The content you requested has been removed.

This peer will be discarded as a time source and NtpClient will attempt to discover a new peer with this DNS name. navigate here Solution: 1. See ME914043 to solve this problem. By default, Windows Server 2003 domain controllers are configured as time servers and use symmetric active mode to send synchronization requests. Time Provider Ntpclient No Valid Response

Microsoft Customer Support Microsoft Community Forums United States (English) Sign in Home Windows Server 2012 R2 Windows Server 2008 R2 Library Forums We’re sorry. Event ID 29 — Local Time Synchronization Updated: November 25, 2009Applies To: Windows Server 2008 The Windows Time service (W32time) synchronizes local time with a time source. See ASP.NET Ajax CDN Terms of Use – http://www.asp.net/ajaxlibrary/CDN.ashx. ]]> Details Event ID: Source: We're sorry There Check This Out At the command prompt, type the following commands in the order that they are given.

At the top of the Start menu, right-click Command Prompt, and then click Run as administrator. Time Provider Ntpclient No Valid Response Has Been Received From Domain Controller Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action. Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free.

Yes No Do you like the page design?

Windows Operating System has a built in "Windows Time" service. The output of above command on my PC was as follows, Value Name      Value Type          Value Data --------------------------------------------- ServiceMain     REG_SZ              SvchostEntry_W32Time ServiceDll      REG_EXPAND_SZ       C:\WINDOWS\system32\w32time.dll NtpServer       REG_SZ              time.windows.com,0x1 Type            REG_SZ              NT5DS Note:- All rights reserved. The Computer Did Not Resync Because No Time Data Was Available In Start Search, type services.msc, and then press ENTER.

The firewall was properly configured to accept NTP port 123 (on the DC side). For example, there is nothing worse than approving updates and they just have… Windows Server 2003 Solar Energy: The Future is Bright Video by: Allison This is a video describing the Use the Show button and then add 123:UDP:xxx.xxx.xxx.xxx/xx, xxx.xxx.xxx.xxx/xx:enabled:W32TM. http://getbetabox.com/event-id/w32time-event-id-32.html Login here!

x 103 Jonathan DeMersseman If the OS on your DCs is Win2k3, this error on your client PCs may indicate a need to apple hotfix ME830092 to your Domain Controllers. net time /setsntp: x 55 Private comment: Subscribers only. Event Details Product: Windows Operating System ID: 29 Source: Microsoft-Windows-Time-Service Version: 6.0 Symbolic Name: MSG_NO_NTP_PEERS_BUT_PENDING Message: The time provider NtpClient is configured to acquire time from one or more time sources, Thanks.

If restarting the Windows Time service does not resolve the issue, restart the computer. This is a topic that greatly interests me and so I decided to produce a video about it. Connect with top rated Experts 16 Experts available now in Live! If you are experiencing a similar issue, please ask a related question Suggested Solutions Title # Comments Views Activity how to check the account lockout counter? 6 53 74d I want

An example of English, please! if so please do let us know the outcomesainath !analyze Sunday, October 25, 2009 3:02 AM Reply | Quote Moderator Microsoft is conducting an online survey to understand your opinion of This posting is provided "AS IS" with no warranties, and confers no rights. Something to maybe remember, by default policy if client time data is out of sync by more then 5 minutes then clients will not be able to log in to the

After you type each command, press ENTER. w32tm /config /manualpeerlist:NTP_server_IP_Address,0x8 /syncfromflags:MANUAL net stop w32time net start w32time w32tm /resync 2. Verify To perform this procedure, you must have membership in Administrators, or you must have been delegated the appropriate authority. In my case, disconnecting the workstation from the problematic domain, connecting it to a different domain, and then reconnecting it to the original domain fixed this problem. Did the page load quickly?

Check the time source configuration, and configure a different time source, if necessary. Copyright 2002-2015 ChicagoTech.net, All rights reserved. By default when any computer is added to domain and domain controller has Time server on it, The client machine starts using DC as time server. x 104 Stein Waalen See ME875424 for a solution to the time synchronization problem.